Online Catalogue | General | Surface Preparation & Coating
Ref: ELCO270PINHOLE
The Elcometer 270 range utilises the wetsponge technique and has beendesigned to set a new standard for wetsponge detectors - namely, a highquality, low voltage detector with similaraccessories to a high voltage sparktester.9V, 67.5V & 90V
Ref: ELCO456BASINT
The Elcometer 456 Integral Gauge with integrated V-groove, is ideal for single handed operation. The wide footprint of the Bigfoot probe provides greater stability when taking readings on flat and curved surfaces.RS232 data output is available using an optional gauge-to-PC cable.
Ref: ELCOADHESION
The standard in the industry for adhesion testing.Easy to use.5 scales available.Adhesion values displayed.Available with 50mm (2inch) dollies.Use in accordance with BS EN 24624, ISO 4624 and ASTM D4541.5 scales cover 0.05 to 22Mpa (5 to 3200psi).
Ref: ELCOBANANA
Measures coatings on ferrous substrates.Ideal for use in hazardous areas.Factory calibrated and user adjustable.Single handed use.Scale range 0 to 1000micron.Accuracy: +/-5% or +/- 2.5micron (0.1mil/thou)
Ref: ELCOCROSSHATCH
The 107 Cross Hatch Cutter provides an instant assessment of the quality of the bond to the substrate. Due to its rugged construction this gauge is ideal for thin, thick or tough coatings on flat or curved surfaces. An ideal field or laboratory test.Low cost Robust designEasy to change cuttersLarge Non slip grip Ideal for thick or hard coatings Large selection of cutters, each with four cutting faces The Basic Kit comes complete with: Robust handle, the cutter of your choice, Allen Key (wrench), presentation storage case and instructions (together with the Classification of Adhesion Test Results Chart)
Ref: ELCOCROSSTAPE
Ref: ELCODEWPOINTCALC
This provides accurate values of Relative Humidity (RH) and Dewpoint from the wet and dry bulb temperatures of a Whirling or Sling Hygrometer.The range is -10ºC to 50ºC (14ºF to 122ºF) and it has an accuracy of ±1% of standard tables.The calculator includes a ºC to ºF converter.
Ref: ELCOM456NON
Ref: ELCOMETER125G
Comparators allow the estimation of surface roughness, by both touch and sight.Available in both Grit and ShotMetric units only
Ref: ELCOMETER125S
Ref: ELCOMETERCOMB1
These reusable precision stainless steel combs are made to be long lasting.Metric comb with 10 thickness measurement steps (teeth) of20, 35, 50, 75, 100, 125, 175, 225, 275, 225, 275, 325µm, manufactured to an accuracy of 5% or 2.5µm (0.01mil), whichever is the greater.Using the Wet Film CombPlace a comb perpendicular to and touching the substrate. Hold the comb in position and wait a few seconds until the teeth are wet. Remove the comb from the film.The wet film thickness lies between the biggest value 'coated' or 'wet' tooth and the smallest value 'uncoated' or 'dry' tooth.
Ref: ELCOMETERCOMB2
These reusable precision stainless steel combs are made to be long lasting.Metric comb with 10 thickness measurement steps (teeth) of51, 76, 102, 152, 203, 254, 305, 356, 406, 457µm, manufactured to an accuracy of 5% or 2.5µm (0.01mil), whichever is the greater.Using the Wet Film CombPlace a comb perpendicular to and touching the substrate. Hold the comb in position and wait a few seconds until the teeth are wet. Remove the comb from the film.The wet film thickness lies between the biggest value 'coated' or 'wet' tooth and the smallest value 'uncoated' or 'dry' tooth.
Ref: ELCOMETERCOMB3
These reusable precision stainless steel combs are made to be long lasting.Metric comb with 10 thickness measurement steps (teeth) of51, 102, 152, 203, 254, 254, 381, 508, 635, 762µm, manufactured to an accuracy of 5% or 2.5µm (0.01mil), whichever is the greater.Using the Wet Film CombPlace a comb perpendicular to and touching the substrate. Hold the comb in position and wait a few seconds until the teeth are wet. Remove the comb from the film.The wet film thickness lies between the biggest value 'coated' or 'wet' tooth and the smallest value 'uncoated' or 'dry' tooth.
Ref: ELCOMETERCOMB4
These reusable precision stainless steel combs are made to be long lasting.Metric comb with 10 thickness measurement steps (teeth) of127, 254, 381, 508, 635, 762, 889, 1016, 1143, 1270µm, manufactured to an accuracy of 5% or 2.5µm (0.01mil), whichever is the greater.Using the Wet Film CombPlace a comb perpendicular to and touching the substrate. Hold the comb in position and wait a few seconds until the teeth are wet. Remove the comb from the film.The wet film thickness lies between the biggest value 'coated' or 'wet' tooth and the smallest value 'uncoated' or 'dry' tooth.
Ref: ELCOMETERCOMBHEX
These hexagonal precision formed stainless steel wet film combs are long lasting and reusable.This six sided comb gives measurement steps of 25, 50, 75, 100, 125, 150, 175, 200, 225, 250, 275, 300, 350, 400, 450, 500, 550, 600, 650, 700, 750, 800, 850, 900, 1000, 1100, 1200, 1400, 1600, 1800, 2000, 2200, 2400, 2600, 2800, 3000µm- Using a Wet Film CombPlace a comb perpendicular to and touching the substrate. Hold the comb in position and wait a few seconds until the teeth are wet. Remove the comb from the film.The wet film thickness lies between the biggest value 'coated' or 'wet' tooth and the smallest value 'uncoated' or 'dry' tooth.
Ref: ELCOMETERCOMBSET
Set of all 4 sizes of Wet Film Comb
Ref: ELCOMETERWFWHEEL
The Wet film Wheel consists of three circles. The central circle is of smaller diameter and is eccentric to the two outer circles. By rolling the gauge through a wet coating, the centre disc eventually touches the film. This point on the scale indicates the thickness.If the volume to solids ratio of the coating is known, then the wet film thickness can be used to predict the dry film thickness.This wheel has a range from 0 to 50µm with scale divisions of 2.5µm * Continuous Scale results in ±5% measurement accuracy.* Suitable for flat and curved surfaces.* Stainless steel giving a hard-wearing instrument which can be cleaned with solvents for reuse.